Water Line Replacement Along Armand St, et al
Louisiana > Lafourche Parish Water District
Sealed Bid: 55717872
Listing Information/Advertisement:


Installation of approximately 7,320 linear feet of 8" water line and appurtenances.

Additional Notes/Requirements
Bids must be submitted on documents provided. Plans and Specifications can be obtained at the office of J. Wayne Plaisance, Inc., the engineer, at 131 East 91st St, Galliano, LA or by calling (985) 632-5596.
SUBMITTAL INFORMATION
Creator Username: LPWD
Bidding Privacy: Bid encryption
Started: 05-Aug-2013 12:00:00 PM CDT
Ends: 29-Aug-2013 2:00:00 PM CDT ( Expired )
History: 1738 Views, 6 Messages
Event Status: Expired since 29-Aug-2013 2:00:00 PM CDT
Actions: Sign-In to Bid
Username:

Password:
Visitors: Visitors/Central Bidding Plan Holders
PUBLIC MESSAGE BOARD
Discuss questions with the owner/creator of this Listing.
HRLContracting on 26-Aug-2013 4:46:16 PM CDT
Bid item 1A includes 8" PVC Pipe w/Tracer Wire C-900 or Diamond Lok-21 or Eagle Loc 900 and Bid item 1B includes 8" PVC Pipe w/Tracer Wire Diamond Lok-21 or Eagle Loc 900. Can you please verfy that Diamond Lok-21 or Eagle Loc 900 should be included in bid item 1A
LPWD on 26-Aug-2013 4:57:56 PM CDT
Bid Item 1A gives you the option to use either of the pipes listed, we are not telling you what pipe to use. Item 1B, we are telling you to use either of the pipes listed. If you choose to use loc pipe in lieu of regular C-900 for Item 1A, you will only be paid the amount shown for Item 1A.
HRLContracting on 26-Aug-2013 5:01:28 PM CDT
Noticed the same thing on bid item 2A & 2B, just need clarification on what product to use.
HRLContracting on 26-Aug-2013 5:04:57 PM CDT
If we decide to use Diamond Lok-21 or Eagle Loc 900 on bid item 1A will we be paid for pipe to pipe restraint?
HRLContracting on 26-Aug-2013 5:18:03 PM CDT
Can you tell me if bid item 9F includes a 6" valve & valve box?
LPWD on 27-Aug-2013 8:54:06 AM CDT
Item 2A & 2B are bores only but yes are the same as previous answer, we are telling you to use Loc Pipe for 2B but 2A is your option. If you use Loc pipe there will be no need to use pipe to pipe restraints. Yes Item 9F includes a 6" valve & valve box.
UPDATE/ADDENDUM HISTORY
All updates/changes are listed below::
14-Aug-2013 8:53:48 AM CDT
Added Memo informing of non-mandatory pre-bid conference.
 
BID HISTORY
Username Bid Amount Type Company name Bid Amount Bid Placed
HRLContracting
Bid Attachments Hensley R Lee Contracting, Inc. =SEALED= 29-Aug-2013 11:51:58 AM CDT
 
TO: The Board of Waterworks Commissioners
Lafourche Parish Water District No. 1
P.O. Box 399
Lockport, LA 70374

FOR: Water Line Replacement
Armand Street, ET AL
August 29, 2013
2:00 pm

FROM: Hensley R Lee Contracting Inc.
311 Aco Lane
Picayune, MS 39466

LOUISIANA CONTRACTORS LICENSE # 47581
Delivery: 0 Days
wallacecdrennan
Bid Attachments Wallace C. Drennan, Inc. =SEALED= 29-Aug-2013 12:19:29 PM CDT
 
FROM:
Wallace C. Drennan, Inc.
Post Office Box 15438
New Orleans, LA 70175-5438

LOUISIANA CONTRACTOR’S LICENSE NO.: 1033

SEALED BID TO:
The Board of Waterworks Commissioners
Lafourche Parish Water District No. 1
Post Office Box 399
Lockport, LA 70374

SEALED BID FOR:
Water Line Replacement : Armand Street, et al
Delivery: 0 Days
Bids Added by Agency/Owner